DIVISION 8 - DOORS AND WINDOWS

 

SECTION 08470 - REVOLVING DOORS

 

TQA AUTOMATIC REVOLVING DOOR

PART I - GENERAL

 

 

1.01               SECTION INCLUDES

 

A.  This section covers the furnishing and installation of a complete Automatic Revolving Door System. Provide complete system that has been fabricated, assembled, and tested for proper operation at the factory. It includes curved sidewalls, canopy, ceiling, access hatch, door wings, hardware, glass, drive system, sensor system and emergency collapsing mechanism as required for installation.

 

 

1.02 RELATED SECTIONS

 

A.  Section 07915 - Sealants, Caulking and Seals

B.  Section 08400 - Entrances and Storefronts

C.  Section 08710 - Door Hardware

D.  Section 08810 - Glass and Glazing

E.   Section 09600 - Flooring

F.   Section 16123 - Electrical Supply and Termination

 

1.03               QUALITY ASSURANCE

 

A. Manufacturer shall be a company specializing in the supply of automatic revolving doors with a minimum of 10 years experience.

 

B. Manufacturer shall supply a factory-trained supervisor during installation of the door.

 

1.04               SUBMITTALS

 

A.  Submit project specific shop drawings, finish samples and Operating & Maintenance Manuals in

             accordance with Section 1.

 

B.  Indicate pertinent dimensions, general construction, component connections and locations, anchorage methods and locations, hardware, and installation details.

 

1.05               DELIVERY, STORAGE AND HANDLING

 

A.  Deliver materials to job site in manufacturer's packaging undamaged, complete with installation instructions.

 

B.  Store off ground, under cover, protected from weather and construction activities.

 

1.06               PROJECT/SITE CONDITIONS

 

A.  Revolving doors install on finished floor only. Floor must not be more than 3/16" out of level at any point within the footprint of the revolving door.

 

1.07               WARRANTY

 

Boon Edam warranties its products against defects in material and workmanship for a period of one (1) year from the date of substantial completion. This warranty excludes glass breakage, normal wear on finishes or damage that occurs due to abuse, misuse or acts of God.

 

PART II - PRODUCTS

 

 

2.01             MANUFACTURER

 

Factory assembled and tested TQA Automatic Revolving Door as manufactured by:

Boon Edam, Inc., 4050 South 500 West, Salt Lake City, Utah 84123.

(801) 261-8980 Fax: (801) 261-1612 Homepage: www.boonedam.com

 

 

AUTHORIZED DISTRIBUTOR:

 

Ontario Door Controls

1350 Matheson Boulevard East

Unit 16, Mississauga

Ontario, Canada.

Phone: (905) 238 9222

Fax    : (905) 238 9279

e-mail: products@automaticdoorsystems.com

 

                            Website: http://www.automaticdoorsystems.com

 

 

2.02    DOOR CONSTRUCTION

 

A.  Curved Side Walls and Canopy: Shall have a standard outside diameter of 10'-0" or 12'-0" and be manufactured from six (6) extruded aluminum posts, six (6) 12" high one-piece extruded aluminum canopies and four (4) extruded aluminum bottom rails with a minimum thickness of 0.125".

 

B.  Door Wings: Three doors manufactured of 1 3/4" thick aluminum extrusions with minimum thickness of 0.125" and reinforced with internal aluminum door corners for strength. Door wings must utilize removable horsehair weather stripping on three sides. Door wings must be capable of folding forward or backward allowing for emergency egress.

 

C.  Ceiling: Shall be fabricated of formed aluminum sheet in a pie-shaped configuration. Each section must be secured in position and removable only by authorized personnel.

 

 

2.03 EQUIPMENT

 

A.  Drive System: Overhead drive system with one 1/4 HP AC motor attached to the internal structural framing. The motor shall be powered by a 208-230 VAC, 3-phase service. The motor shall utilize an internal angle encoder for constant monitoring of door position and a Frequency Controller to provide for the following characteristics:

1.      Adjustment of rotation speed through a digital setting

2.      Constant regulation of rotation speed

3.      Adjustment of startup/run torque through a digital setting to minimize force required to stop door

4.      Adjustment of stopping distance through a digital setting

5.      Password-protected security over Frequency Control settings

 

B.  Braking Assembly: Positive braking and stopping shall be performed by electromagnetic brake assembly incorporated within the drive system. The brake unit is to remain unlocked at all times until locked by electric locking system.

 

C.  Controls: Microprocessor-based electronics utilizing a 2000-step Programmable Logic Controller (PLC) with the following characteristics:

1.      RAM & ROM memory

2.      Lithium battery backup

3.      Self-diagnostics for quick detection of problem source

4.      Visual display of problem source

 

D. Emergency Collapsing Mechanism: Precision-engineered door hangers and disks to allow the door wings to be collapsed, or folded and stored in a bookfold position. Hangers and disks are finished in black and provide tension to hold the door wings in position when the electric locking is released. The wings shall be capable of being collapsed outward under pressure on the outer stile not to exceed 180 pounds.

 

E.   Pivot: Floor mounted pivot under the center shaft to provide smooth rotation.

 

F.  Center Shaft: Extruded aluminum shaft with multi-point connections to the drive assembly and pivot.

 

G.  Electric Locking: A fail-safe electromagnetic shaft and wing lock mechanism with a (2) position post-mounted key switch to activate locking. When engaged, the electric locking will prevent rotation or collapsing of the door wings. Electric locking is disengaged by loss of power or signal from building/fire/smoke alarm (Requires a (5) wire system, 208V (3) Phase, 60Hz, 20A, service from above, by others).

 

H.  Surface Applied Slide Bolt Locks (Optional): Two (2) standard 1 3/4" x 5 5/8" surface-mounted deadbolt locks with removable keyed cylinders that lock into the ceiling or floor on the two interior door wings.

 

I.    Two-Point Recessed Locks (Optional): Two (2) standard concealed two point recessed locks with removable keyed cylinders that lock into the ceiling and floor on the two interior door wings.

 

J.   Anti-Entrapment Sensors (Optional): Sensors in the ceiling that detect an individual inside the revolving door compartments after the door has been locked electrically, and disengages the shaft locking mechanism for rotation of one additional segment to prevent entrapment. Required only when remote or timer control is used to engage optional electric locking.

 

K.  Lights: Provide (4) 5" diameter 50W Halogen lights to be recessed into ceiling (110V power service required from above by others.).

 

 

2.04    SENSOR SYSTEM

 

A.  M.M.S. Microwave Motion Detectors: Two (2) microwave motion detectors mounted to the canopy on each side of the door that will start the rotation of the door upon actuation. Detection pattern must be adjustable directly or by remote control.

 

B.  T.R.S. Sensors: Active infrared sensors mounted to the top rail of each door wing that will detect presence in front of each door wing and stop the door immediately. Sensors must be adjustable for pattern size and distance from door wing.

 

C.  E.B.S. Sensors: Two (2) active infrared sensors mounted vertically in front of the curved side walls that will detect presence and stop the door immediately. The EBS sensors should be capable of switching on as each door wing approaches the endpost of each side wall and off as each door wing departs the endpost of each side wall.

 

D.  S.R.B. (Sensor Rail Bentwall): A multi-directional, closed-contact pressure sensitive switch contained within a black rubber profile mounted to the edge of each inbound endpost that will immediately stop the door's rotation if compressed.

 

E.  S.R.D. (Sensor Rail Doorwing): A multi-directional, closed-contact pressure sensitive switch contained within a black rubber profile mounted to the bottom rail of each door wing that will immediately stop the door's rotation if compressed.

 

F.   Handicap Button: Two (2) Handicap "Push to Slow" Buttons mounted on the inbound endposts that will reduce the rotating speed of the revolving door to approximately 1/2 the regular speed for approximately one revolution.

 

G.   Emergency Stop Button: Two (2) Emergency Stop Buttons mounted on the inbound endposts that will immediately stop the door when pressed.

 

H.  Key Switch: A two-position key switch mounted on the interior endpost that will turn the door on/off.

 

 

2.05   HARDWARE/MATERIALS

 

A.  Tempered Glass: All flat glass in door wings shall be 1/4" clear tempered safety glass, all curved glass shall be 1/4" clear bent tempered safety glass.

 

B.  Laminated Glass (Optional): 7/16" clear curved laminated safety glass is available as an option.

 

C.   Aluminum Extrusions: Heavy-duty aluminum extrusions with minimum thickness of 0.125.

 

D.   Weather Stripping: Genuine horsehair weather-stripping on all required edges of door wings.

 

E.  Bumpers: rigid, rubber-tipped bumper on each door wing to prevent push bar from contacting the glass of the adjacent door

 

F.   Rubber Seal: Rubber profiles to seal glazing, ceiling ring, and/or any other joints or gaps requiring weather-resistant seal.

 

G.  Pivot: Floor mounted pivot under the center shaft to provide smooth rotation.

 

H.  Center Shaft: Extruded aluminum shaft with connections to the drive system and pivot.

 

2.06    FINISH

 

A.  Enclosure Walls: Anodized aluminum, kynar painted or powder-coated aluminum, stainless steel or architectural bronze (muntz metal) clad.

 

B.  Rotating Doors and Shaft: Anodized aluminum, kynar painted or powder-coated aluminum, stainless steel or architectural bronze (muntz metal) clad.

 

C.  Ceiling: Anodized aluminum, kynar painted or powder-coated aluminum, stainless steel or architectural bronze (muntz metal) clad.

 

PART III EXECUTION

 

 

3.01 INSTALLATION

 

A.   Inspection: Installer must examine the location and advise the Contractor of any site conditions unacceptable

      for proper installation of product. These conditions include but are not limited to the following:

1.      Floor out of level more than 3/16" at any point within the footprint of the door

2.      Finished floor not yet installed

Installation shall not begin until these unacceptable conditions are rectified.

 

B.  Erection: Install revolving doors in accordance with manufacturer's printed instructions. Set units level, plumb, and with uniform hairline joints. Anchor securely into place. Use only factory-trained installers.

 

C.   Adjustment: Installer shall adjust door, hardware and sensors for smooth operation and proper performance.

 

D.   Instruction: A factory trained installer shall demonstrate to the owner's maintenance crew the proper operation of the door and the necessary service requirements such as lubrication, cleaning, and inspection of components.

 

E.  Cleaning: Clean metal and glass surfaces carefully after installation to remove excess caulk, dirt and labels.

 

 

Boon Edam, Inc. reserves the right to change this specification at any time without notice.