DIVISION 8 DOORS AND WINDOWS

 

SECTION 08470 - REVOLVING DOORS

 

TRITOUR AUTOMATIC REVOLVING DOOR

PART I - GENERAL

 

 

1.01    SECTION INCLUDES

 

A.  This section covers the furnishing and installation of a complete Automatic Revolving Door System. Provide complete system that has been fabricated, assembled, and tested for proper operation at the factory. It includes curved side walls, canopy, ceiling, access hatch, door wings, hardware, glass, drive system, sensor system and emergency collapsing mechanism as required for installation.

 

 

1.02   RELATED SECTIONS

 

A.  Section 07915 - Sealants, Caulking and Seals

      B.  Section 08400 - Entrances and Storefronts

C.  Section 08710 - Door Hardware

D.  Section 08810 - Glass and Glazing

      E.  Section 09600 - Flooring

F.   Section 16123 - Electrical Supply and Termination

 

 

1.03   QUALITY ASSURANCE

 

A. Manufacturer shall be a company specializing in the supply of wide-body automatic revolving doors with a minimum of 10 years experience.

 

B. Manufacturer shall supply a factory-trained supervisor during installation of the door.

 

 

1.04   SUBMITTALS

 

A.  Submit project specific shop drawings, finish samples and Operating & Maintenance Manuals in accordance with Section (       ).

 

B.  Indicate pertinent dimensions, general construction, component connections and locations, anchorage methods and locations, hardware, and installation details.

 

 

1.05   DELIVERY, STORAGE AND HANDLING

 

A.  Deliver materials to job site in manufacturer's packaging undamaged, complete with installation instructions.

 

B.  Store off ground, under cover, protected from weather and construction activities.

 

1.06   PROJECT/SITE CONDITIONS

 

A.  Revolving doors install on finished floor only. Floor must not be more than 3/16" out of level at any point within the footprint of the revolving door.

 

 

1.07   WARRANTY

 

Boon Edam warranties its products against defects in material and workmanship for a period of one (1) year from the date of substantial completion. This warranty excludes glass breakage, normal wear on finishes or damage that occurs due to abuse, misuse or acts of God.

 

 

 

PART II - PRODUCTS

 

 

2.01   MANUFACTURER

Factory assembled and tested Tritour Automatic Revolving Door as manufactured by:

Boon Edam, Inc., 4050 South 500 West, Salt Lake City, Utah 841 23.

(801) 261-8980  Fax: (801) 261-1612  Homepage: www.boonedam.com

 

AUTHORIZED DISTRIBUTOR:

 

Ontario Door Controls

1350 Matheson Boulevard East

Unit 16, Mississauga

Ontario, Canada.

Phone: (905) 238 9222

Fax    : (905) 238 9279

e-mail: products@automaticdoorsystems.com

 

                            Website: http://www.automaticdoorsystems.com

 

 

2.02    DOOR CONSTRUCTION

 

A.  Curved Side Walls and Canopy: Shall have an outside diameter of 10'-0" or 12'-0" and be manufactured from six (6) heavy-duty aluminum posts with minimum thickness of 0.25", three (3) 12" high one-piece extruded aluminum canopy sections with minimum thickness of 0.125" and four (4) extruded aluminum bottom rails with minimum thickness of 0.125".

 

B.  Door Wings: Three doors shall be 2 1/4" (not 1 3/4") thick aluminum extrusions with minimum thickness of 0.125" and reinforced in the corners with solid aluminum machined bar stock for strength. Door wings must utilize removable horsehair weather stripping on all four sides. Double-acting doors are held in position with non-jamming electromagnetic locks. Upon release by door controls, or building/fire/smoke alarm, door must be capable of folding forward or backward to allow for emergency egress.

 

C.  Center Section: Shall be manufactured from steel tubing and aluminum sheet with connections to the drive system and pivot bearing.

 

D.  Ceiling: shall be fabricated of formed aluminum sheet in a segmented configuration. Each section must be secured in position and removed only by authorized personnel.

 

2.03   EQUIPMENT

 

A.  Drive System: Overhead drive system with one 1/2 HP AC motor attached to the internal structural framing. The motor shall be powered by a 208-230 VAC, 3-phase service. The motor shall utilize an internal angle encoder for constant monitoring of door position and a Frequency Controller to provide for the following characteristics:

 

1.      Adjustment of rotation speed through a digital setting

2.      Constant regulation of rotation speed

3.      Independent adjustment of startup and run torque through a digital setting to minimize force required to stop door

4.      Adjustment of stopping distance through a digital setting

5.      Removable remote control programmer for security over Frequency Control settings

 

B.  Braking Assembly: Positive braking and stopping shall be performed by electromagnetic brake assembly incorporated within the drive unit. The brake unit to remain unlocked at all times until locked by electric locking system.

 

C.  Controls: Must be microprocessor-based electronics utilizing a 2000-step Programmable Logic Controller (PLC) with the following characteristics:

 

1.      RAM & ROM memory

2.      Lithium battery backup

3.      Self-diagnostics for quick detection of problem source

4.      Visual display of problem source

 

D.  Pivot Bearing: Floor mounted pivot bearing under the center section to provide smooth rotation.

 

E.      Storm Coupling: Fail-safe electromagnetic lock device connected to the top shaft of each door wing to hold the door wings firmly during normal operation. Upon signal from the building/fire/smoke alarm system, the storm couplings retract allowing the door wings to be collapsed, or folded, allowing for emergency egress.

 

F.      Surface Applied Slide Bolt Locks (Optional): Two (2) standard 1 3/4" x 5 5/8" surface-mounted deadbolt locks with removable, keyed cylinders that lock into the ceiling or floor on the two interior door wings.

 

G.     Two-Point Recessed Locks (Optional): Two (2) standard concealed two point recessed locks with removable, keyed cylinders that lock into the ceiling and floor on the two interior door wings.

 

H.     Lights: Three (3) 5" diameter SOW Halogen lights to be recessed into the rotating ceiling. Additional lights in the fixed ceiling pies require a separate 1OV power service by others.

 

 

2.04               SENSOR SYSTEM

 

A.  M.M.S. Microwave Motion Detectors: Two (2) microwave motion detectors mounted to the canopy on each side of the door that will start the rotation of the door upon actuation. Detection pattern must be adjustable directly or by remote control.

 

B.  T.R.S. Sensors: Active infrared sensor mounted to the top rail of each door wing that can detect presence in front of each door wing and stop the door immediately. Sensors must be adjustable for pattern size and distance from door wings.

 

C.  E.B.S. Sensors: Two (2) active infrared sensors mounted vertically in front of the curved side walls that will detect presence and stop the door. The EBS sensors should be capable of switching on as each door wing approaches the endpost of the side wall and switching off as each door wing departs the endpost of each side wall.

D.  S.R.B. (Sensor Rail Bentwall): A multi-directional, closed-contact pressure sensitive switch contained within a black rubber profile mounted to the edge of each inbound endpost that will immediately stop the door's rotation if compressed.

 

E.   S.R.D. (Sensor Rail Doorwing): A multi-directional, closed-contact pressure sensitive switch contained within a black rubber profile mounted to the bottom rail of each door wing that will immediately stop the door's rotation if compressed.

 

F.   Handicap Button: Two (2) Handicap "Push to Slow" Buttons mounted on the inbound endposts that will reduce the rotating speed of the revolving door to approximately 1/2 the regular speed for approximately one revolution.

 

G. Emergency Stop Button: Two (2) Emergency Stop Buttons mounted on the inbound endposts that will immediately stop the door when pressed.

 

H.  Key Switch: A two-position key switch mounted on the interior endpost that will turn the door on/off.

 

 

2.05               HARDWARE/MATERIALS

 

A.  Tempered Glass: All flat glass in door wings shall be 1/4" clear tempered safety glass, all curved glass shall be 1/4" clear bent tempered safety glass.

 

B.  Laminated Glass (Optional): 7/16" clear curved laminated safety glass is available as an option.

 

C.  Aluminum Extrusions: Heavy-duty aluminum extrusions with minimum thickness of 0.125.

 

D.  Weather Stripping: Genuine horsehair weather stripping on all required edges of door wings.

 

E.   Bumpers: rigid, rubber-tipped bumper on each door wing to prevent push bar from contacting the glass.

 

F.   Rubber Seal: Rubber profiles to seal glazing, ceiling ring, and/or any other joints or gaps requiring weather­resistant seal.

 

G.  Pivot Bearing: Floor mounted pivot bearing under the center shaft to provide smooth rotation.

 

 

2.06       FINISH

 

A.  Enclosure Walls: Anodized aluminum, kynar painted or powder-coated aluminum, stainless steel or architectural bronze (muntz metal) clad.

 

B.     Rotating Doors and Center Core: Anodized aluminum, kynar painted or powder-coated aluminum, stainless steel or architectural bronze (muntz metal) clad.

 

C.  Ceiling: Anodized aluminum, kynar painted or powder-coated aluminum, stainless steel or architectural bronze (muntz metal) clad.

 

PART III - EXECUTION

 

3.01               INSTALLATION

A. Inspection: Installer must examine the location and advise the Contractor of any site conditions unacceptable for proper installation of product. These conditions include but are not limited to the following:

1.      Floor out of level more than 3/1 6" at any point within the footprint of the door

2.      Finished floor not yet installed

Installation shall not begin until these unacceptable conditions are rectified.

 

B.  Erection: Install revolving doors in accordance with manufacturer's printed instructions. Set units level, plumb, and with uniform hairline joints. Anchor securely into place. Use only factory-trained installers.

 

C. Adjustment: Installer shall adjust door, hardware and sensors for smooth operation and proper performance.

 

D. Instruction: A factory trained installer shall demonstrate to the owner's maintenance crew the proper operation of the door and the necessary service requirements such as lubrication, cleaning, and inspection of components.

 

E.   Cleaning: Clean metal and glass surfaces carefully after installation to remove excess caulk, dirt and labels.

 

 

Boon Edam, Inc. reserves the right to change this specification at any time without notice.