GT SYSTEM 1100 "WHISPERSLIDE"
SERIES
MODEL 1175
SUGGESTED ARCHITECTURAL SPECIFICATIONS
SECTION 8
AUTOMATIC ENTRANCE SYSTEMS
Part 1-GENERAL
1.01 DESCRIPTION
A.
Furnish and install automatic equipment as indicated on drawings and
specifications.
B.
Related work specified elsewhere.
1. Electrical Supply
Section: __________ _________________
1.02 QUALITY ASSURANCE
A.
Manufacturer's Qualifications:
Products specified shall be represented by a
factory authorized and trained distributor. Distributor shall maintain a parts
inventory and trained service personnel capable of providing service.
B.
All automatic equipment to comply with ANSI A156.10.
C. Gyro Tech equipment as
manufactured by NABCO ENTRANCES, INC. has been specified and shall be quoted
as a base bid. Other systems can be quoted along with information specifically
detailing the differences from the following specification.
1.03 SUBMITTALS
A.
Shop drawings showing complete elevations, details and methods of
anchorage to location; installation of hardware; size, shape, joints and
connections; and details of joining with other construction.
B.
Templates and diagrams and/or shop drawings as needed shall be
furnished to fabricators and installers of related work for coordination of
sliding door system with concrete work, electrical work, and other related
work.
C.
A copy of appropriate manual shall be provided to owner's
representative upon completion of installation.
1.04 WARRANTY
A.
Warranty power operators, controls and labor provided by automatic
sliding door equipment installer against defects in material and workmanship,
at no cost to owner, for a period of one year from date of substantial
completion. Provide warranty to owner after completion of installation.
1.06 COMPLIANCE
A.
Completed American Association of Automatic Door Manufacturer (AAADM)
form shall be submitted as proof of compliance with ANSI A156.10 Standard for
power operated pedestrian doors. Door(s) shall be inspected and form shall be
signed by an AAADM certified inspector prior to placing door(s) in operation.
Part 2-PRODUCTS
2.01 APPROVED DISTRIBUTER
Ontario
Door Controls
1350 Matheson Boulevard East
Unit 16, Mississauga
Ontario, Canada.
Phone: (905) 238 9222
Fax
: (905) 238 9279
e-mail:
products@automaticdoorsystems.com
Website: http://www.automaticdoorsystems.com
2.02 AUTOMATIC GT "WHISPERSLIDE" SYSTEM
A.
GT Model #1175 Whisperslide as indicated on door schedule and
details.
B.
Mode of operation: Sliding door shall be driven by an
electro-mechanical operator with a micro-computer control system. The door
will be pulled from closed to open and open to close position stopping the
door in both directions by electrically reducing the voltage, stalling door
against mechanical stop. Opening, closing speeds and hold open time shall be
adjustable. A reinforced timing belt shall be used to convert rotating motion
from the operator sprocket into horizontal motion of the door
C.
Components:
1. Aluminum doors, sidelites,
operator housing and frame.
2. Rollers-support, anti-riser
and guide.
3. Door carrier hanger assembly, breakaway latch,
limiting arm and door lock.
4. Air infiltration and intrusion
protection equipment.
5. Gyro Tech Whisperslide power close operator
with micro-computer control.
6. (Optional) Access Security
Equipment
1a)
Door panel(s) and sidelite(s) panel shall be factory assembled with
3/8"-16 threaded tie rods spanning full length of top and bottom rails.
Snap-in glass stop with integral extruded vinyl standoff to accommodate glass
flexing. A horizontal muntin bar to provide glass protection.
1b)
Operator housing section shall be three piece construction
6-1/2"(165.10 mm) by 7-1/2"(190.5 mm) extrusion with enclosed end
caps. All header sections shall have a minimum thickness of 0.140"
(3.6mm) and shall be fabricated of 6063-T5 aluminum alloy.
1c)
Sidelite configuration shall be fixed, full breakaway or pocket type.
1d)
Finish: Aluminum shall have a standard finish of AA-M12-C22-A31 (204R1,
clear) or AA-M12-C22-A42 (dark bronze). Black and special finishes available
upon request.
1e)
Vertical jambs shall be of 1-3/4" (44.4mm) by 4-1/2"
(114.3mm) extruded aluminum tubes. 1-3/4" (44.45mm) by 6-3/8"
(161.93mm) for pocket type units. Optional framing available.
2a)
The door assembly shall ride on two 2-11/16" (68.3mm) dia. support
rollers incorporating lubricated sealed ball bearings rated at 250 lbs. each.
The door shall be held on the track by means of two 2-7/16" (62.2mm)
anti-riser rollers. Lateral adjustment of the door assembly shall provide
positive sealing at door edges. Door height shall be adjustable by 9/32"
(7.1mm).
2b)
Fixed Sidelite and Pocket Units - Each door shall include one guide
assembly incorporating double rollers with sleeve bushings. Guide assembly
shall be attached to the door with 10 gauge (3.44mm) thick-formed guide
bracket. All steel brackets and fittings shall be plated for corrosion
resistance.
2c)
Full Open Units - Each door shall include one guide assembly
incorporating one roller and bottom guide riding in a surface or recessed
floor track assembly.
3a)
Entrance systems shall have door panels attached to a door carrier
assembly by means of an adjustable support rod pivot assembly and corrosion
resistant adjustable breakaway release latch holding panel in the closed
position under normal automatic operation. The support rod pivot assembly
allows the door panel to be broken outward at any point in the door's opening
or closing cycle allowing for safe emergency egress in compliance with NFPA
101. The door panel in the breakout mode disconnects the power to the control
circuit inhibiting automatic door operation. The control circuit shall be
reset by re-engaging the door panel with the door carrier assembly. Breakaway
pressure shall be field adjustable (5-50 lbs.) to meet local building code
requirements but will be factory set at 50 lbs. maximum.
3b)
Door assembly shall have a limiting arm to control the door as it
swings in the direction of egress.
3c)
The active door will incorporate a two-point lock securing the lead
stiles and door carrier assembly. In the case of a single slider, securing at
the jamb and door carrier assembly. The lock assembly will incorporate a key
cylinder on the exterior and a thumb turn on the interior in accordance with
NFPA 101.
4)
Double pile weatherstripping on the lead edge of the sliding door(s)
.36" thick (9.1mm) including the area of the lock.
4a)
11/16" (17.3mm) wide nylon brush weatherstripping on the vertical
stile of both the sliding door panel(s) and sidelite(s) panels
4b)
11/16" (17.3mm) wide nylon brush weatherstripping mounted on door
bottom.
5)
GyroTech Whisperslide Power Operator: Completely assembled and sealed
unit which shall include gear-driven transmission, and bearings, all located
in cast aluminum housing and filled with special lubricant for extreme
temperature conditions. Attached to transmission system shall be a DC
shunt-wound permanent magnet motor with sealed ball bearings. 1/10 HP motor
shall operate from 115-volt supply and require less than 5 amps at full stall.
5a)
Power Operator Control: Shall be a microprocessor unit. To facilitate
service and continuing operations, the unit supplied with the slider shall
also be able to operate other doors supplied for the project including swing
or folding types. The microprocessor control shall allow the opening speed,
closing speed, back check speed and latch check speed each to be adjusted
separately and independently from each other to meet specific site conditions.
The doors shall be set to be held closed with the motor. The control system
shall also be set up to provide a count of the number of operations of the
doors for maintenance purposes. Adjustable opening and closing speeds shall be
set in accordance with ANSI 156.10. All adjustments shall be specific and
reproducible. Settings with rotary switches are not allowed.
6)
Access Security Equipment: Shall consist of Gyro Tech 24 V.D.C. power
locking device. Lock shall be concealed in header. Sliding door to be fitted
with Adams Rite 8600 Concealed Vertical Rod tamper proof exit device.
2.03 SENSOR DEVICES
A.
Acusensor: Manufactured by NABCO ENTRANCES, INC.
Sensors for door activation and threshold sensing
shall provide a rectangular shaped pattern with a sensing area next to the
door system. To provide optimum coverage to meet specific site conditions the
sensing pattern shall be adjustable both in width and depth of coverage while
remaining at a full power setting. Units shall be supplied and installed on
both sides of the operator housing to activate doors for single or two-way
traffic. Units shall be sealed for protection against dust, moisture and the
elements.
B.
Specification options for consideration:
1. Mats
2. Wall Switches
3. For others see product catalog.
PART 3- EXECUTION
3.01 INSTALLATION
A.
Automatic door equipment shall be installed by factory-trained
installers in compliance with manufacturer's recommendations and approved shop
drawings.
3.02 CLEANING AND PROTECTION
A.
After installation, clean framing members as recommended by the
manufacturer. Aluminum surfaces in contact with masonry, concrete or steel
shall be protected by use of neoprene gaskets, where indicated, or a coat of
bituminous paint to prevent galvanic or corrosive action. Advise general
contractor to protect unit from damage during subsequent construction
activities.
*COVER NOTE TO
SPECIFICATION WRITER
Indicate under
appropriate Section the following work by others:
ELECTRICAL INSTALLER shall furnish and
install all conduit and electrical wiring for activating devices and door
operators. A minimum of 5 amperes, 115 volts, A/C, 1-phase circuit shall be
furnished for each door operator, terminate and connect to operator control
panel, in operator housing.
CONCRETE INSTALLER shall prepare floor at
location of automatic entrance system to accommodate the surface or recessed
electric switch mats indicated on drawings.