GT SYSTEM 1200 MANUAL SLIDER
I.C.U./CC.U
TRACKLESS MODEL
Suggested Architectural Specifications
SECTION 8
MANUAL ENTRANCE SYSTEMS
PART 1-GENERAL
1.01
DESCRIPTION
A.
Furnish and install door equipment as indicated on drawings and
specifications.
B.
Related work specified elsewhere.
1.
Prepared Opening: Section
2.
Glazing: Section _______
1.02 QUALITY ASSURANCE
A.
Manufacturer's Qualifications:
Products specified shall be represented by a factory authorized and trained
distributor. Distributor shall maintain a parts inventory and trained
personnel capable of providing service.
1.03 SUBMITTALS
A.
Shop drawings showing complete elevations, details and method of
anchorage to location; installation of hardware; size, shape and thickness of
materials; joints and connections; and details of joining with other
construction.
B.
Templates and diagrams and/or shop drawings as needed shall be
furnished to fabricators and installers of related work for coordination of
doors, frames, hardware, concrete work and other work.
C.
A copy of appropriate maintenance manual shall be provided to owner’s
engineer upon completion of installation.
1.04 WARRANTY
A.
Warrant all material and labor provided by automatic door equipment
installer against defects in material and workmanship at no cost to owner, for
a period of one year from date of substantial completion. Provide warranty to
owner after completion of installation.
PART 2-PRODUCTS
2.01 APPROVED MANUFACTURER
A. All
door equipment shall be distributed by:
Ontario Door Controls
1350 Matheson Boulevard East
Unit 16, Mississauga
Ontario, Canada.
Phone: (905) 238 9222
Fax
: (905) 238 9279
e-mail:
products@automaticdoorsystems.com
Website: http://www.automaticdoorsystems.com
2.02 MANUAL SLIDING DOOR SYSTEM
GYRO Slide System 1200
A.
Mode of Operation: The GYRO TECH Series 1200 Intensive Care (I.C.U.)/Cardiac
Care Unit (I.C.U.) package provides the unique feature of room access without
a floor track. Smooth entry and exit is provided for patient and also for
delicate medical equipment. This feature also precludes the chance of
contaminant build up. Under normal operating conditions, medical personnel
have access by way of the sliding door. When patient and/or medical equipment
access is required, the sliding door is moved to the breakaway position
capturing the transfer pivot. At this location, the door and swing panel
becomes a pivoting unit and can swing 90 degrees giving access to
approximately 95% of the framed opening. Reset procedures occur in reverse
order.
B. Product
Components:
1.
Aluminum doors, swing panels and frame assembly.
2.
Rollers - Support and Guide.
3.
Door carrier hanger assembly, swing panel pivots, breakaway latches,
limiting arms, pull handles, static arrester, and weathering seal.
1a)
Door panel and Swing panel shall be factory assembled with 3/8-16
threaded tie rods spanning full length of top and bottom rails. Snap in glass
stop with integral extruded vinyl standoff to accommodate glass flexing. A
horizontal muntin bar to provide glass protection.
1b)
Vertical Jambs and Horizontal Header shall be 1-3/4 x 4-1/2" (44.4
mm x 114.3 mm) extruded aluminum tubes. High strength KB-45 aluminum roller
track shall be mounted and fastened inside the header and shall be replaceable
in the event of damage.
1c)
All major extrusions to be minimum .125 (3.2 mm) wall thickness.
1d)
All extruded aluminum sections shall be 6063-T5 or equivalent.
1e)
Finish: Aluminum shall have a standard finish of AA-M12-C22-A41 (204
R1) or AA-M12-C22-A4
(dark bronze). Black
and special finishes available upon request
3.
Sliding door suspension provided by two, three wheeled nylon roller
assemblies rated at 200 lbs. each. Each roller assembly shall have + 1/8"
(3.l8mm) of vertical adjustment. Each swing panel shall include one
spring-loaded bottom guide roller assembly, incorporating a rubber outer shell
and lubricated sealed ball bearing. Guide roller shall be attached to the
swing panel with a 1/4" (6.35 mm) thick-formed guide bracket. All steel
brackets and fitting shall be plated for corrosion resistance.
3a)
Entrance systems shall have door panels attached to a door carrier
hanger assembly by means of an adjustable support rod pivot assembly and
corrosion resistant adjustable breakaway release latch holding the door panel
in the closed position under normal manual operation. The support rod pivot
assembly allows door to swing freely in panic mode without sagging. The system
shall have breakaway swing panels held in place by means of a top pivot and
floor pivot plate secured to the floor and a corrosion resistant adjustable
breakaway release latch for holding the panel in the closed position.
Breakaway pressure shall be field adjustable (5-50 lbs.) to meet local
building code requirements but will be factory set at 50 lbs. maximum.
3b)
All panels shall have a limiting arm to control the panel swing in the
direction of egress.
3c)
Door pull adjacent to swing panel is of recessed type to preclude pinch
point. External door activation is provided by a pull handle.
3d)
An electrical grounding system on each door grounds entrance package
from static electricity.
3e)
15/16" wide vinyl strip seal positioned between the door(s) and
lead stile(s) of the swing panel(s).
PART 3-EXECUTION
3.01 INSTALLATION
Door equipment shall be
installed by manufacturer-approved, factory -trained installers in compliance
with manufacturer's recommendations and approved shop drawings.
3.02 CLEANING AND PROTECTION
After installation, clean
framing members as recommended by manufacturer. Aluminum surfaces in contact
with masonry, concrete, or steel shall be protected by use of neoprene gaskets
where indicated or a coat of bituminous paint to prevent galvanic or corrosive
action. Advise general contractor to protect unit from damage during
subsequent construction activities.
*COVER NOTE
TO SPECIFICATION WRITER
A.
Preparation of a plumb and square opening to receive sliding door
equipment with adequate support.
B.
Glass and glazing shall be described in glazing section of the
specifications.