GT SYSTEM 1400 BI-FOLD
SUGGESTED ARCHITECTURAL SPECIFICATIONS
SECTION 8
AUTOMATIC ENTRANCE SYSTEM
Part 1 - GENERAL
1.01 DESCRIPTION
A. Furnish and install
automatic equipment as indicated on drawings and specifications.
B.
Related work specified elsewhere.
1. Electrical Supply:
Section________
1.02 QUALITY ASSURANCE
A.
Manufacturer's Qualifications:
Products specified shall be represented by a
factory authorized and trained distributor. Distributor shall maintain a parts
inventory and trained service personnel capable of providing service.
B.
Gyro Tech equipment as manufactured by NABCO ENTRANCES, INC. has been
specified and shall be quoted as the base bid. Other systems can be quoted
along with information specifically detailing the differences from the
following specification.
1.03 SUBMITTALS
A.
Shop drawings showing complete elevations, details and methods of
anchorage to location; installation of hardware; size, shape, joints and
connections; and details of joining with other construction.
B.
Templates and diagrams and/or shop drawings as needed shall be
furnished to fabricators and installers of related work for coordination of
Bi-fold system with concrete work, electrical work, and other related work.
C.
A copy of appropriate manual shall be provided to owner’s engineer
upon completion of installation.
1.04 WARRANTY
A.
Warranty power operators, controls and labor provided by automatic
Bi-fold equipment installer against defects in material and workmanship, at no
cost to owner, for a period of one year from date of substantial completion of
installation. Provide warranty to owner after completion of installation.
1.05 COMPLIANCE
A.
Completed American Association of Automatic Door Manufacturer (AAADM)
compliance form shall be submitted as proof of compliance with ANSI A156.10
Standard for power operated pedestrian doors. Door(s) shall be inspected and
form shall be signed by an AAADM certified inspector prior to placing door(s)
in operation.
Part 2-PRODUCTS
2.01 APPROVED MANUFACTURER
A.
Automatic equipment and controls shall be distributed by:
Ontario
Door Controls
1350 Matheson Boulevard East
Unit 16, Mississauga
Ontario, Canada.
Phone: (905) 238 9222
Fax
: (905) 238 9279
e-mail:
products@automaticdoorsystems.com
Website: http://www.automaticdoorsystems.com
2.02 AUTOMATIC BI-FOLD SYSTEM
A.
GT 1400 Bi-fold as indicated on door schedule and details.
B.
Mode of operation: Gyro-Swing operator shall open door by energizing
motor and shall stop door by electrically reducing voltage and stalling motor
against mechanical stop. Door shall close by means of spring energy, and
closing force shall be controlled by gear system and motor being used as
dynamic brake without power. Opening and closing speeds shall be adjustable.
Door operation shall not require any fluids or gases under pressure to be used
in opening and closing door.
C.
Components:
1. Aluminum panels, operator
housing and frame.
2. Gyro-Swing Power Operator.
3. Computerized Control
4. Connecting Hardware
5. Air infiltration and intrusion
protection
6. Doorway holding beams
1a)
Aluminum panels: Bi-fold available in two or four panel
configurations. Door (FX) and sidelite (FS) panels shall be factory assembled
with 3/8"-16 threaded tie rods spanning full length of top and bottom
rails. Snap-in glass stop with integral extruded vinyl standoff to accommodate
glass flexing. A horizontal muntin bar to provide glass protection as required
by UL standard 325.
1b) Operator Housing: Bi-fold housing
shall be 5- ½" (139.7 mm) wide by 7-½" (190.50 mm) high aluminum
extrusion with enclosed end caps. All header sections shall have a minimum
thickness of 0.167"(4.3mm) and shall be fabricated of 6063-T5 aluminum
alloy.
1c)
Finish: Aluminum shall have a standard finish of AA-M12-C22-A41
(204R1, clear) or AA-M12-C22-A42 (dark bronze). Black and special finishes
available upon request.
1d)
Vertical jambs shall be of 2" (50.8 mm) by 5" (127.0mm)
extruded aluminum tubes. Optional framing available.
2)
Gyro-Swing Power Operator: Completely assembled and sealed unit which
shall include helical gear-driven transmission, mechanical spring and
bearings, all located in cast aluminum housing and filled with special
lubricant for extreme temperature conditions. Attached to transmission system
shall be a DC shunt-wound permanent magnet motor with sealed ball bearings.
Motor shall operate from 115-volt supply and require less than 5 amps at full
stall. Complete unit shall be resilient mounted with provisions for easy
replacement without removing door from pivots or frame.
3)
Computerized Control: Control shall be a Universal Control capable of
operating swing or slide units. Adjustable opening and closing speeds shall
enable operation in accordance with ANSI 156.10 or 156.19 as desired. All
adjustments to be made by an authorized Gyro Tech Entrances distributor by
means of a Handy Terminal.
4)
Connecting Hardware: There shall be positive mechanical connections
between all operating parts. Belts or other devices, shall not be allowed.
5a)
Air infiltration and intrusion protection: Double ¼" (6.35 mm)
thick pile weather stripping on lead and pivot edge of door panel (FX) and
sidelite (FS) panel.
5b)
Finger guard protection located at leading edge of the door (FX) and
the pivot stile of the sidelite (FS).
5c)
Optional locking configurations available upon request. The lock
assemblies will incorporate a key cylinder on the exterior and a thumb turn on
the interior in accordance with NFPA 101.
5d)
The door panel may be broken outward at any point during the opening or
closing cycle allowing for emergency egress in compliance with NFPA 101. The
door panel in the breakout mode disconnects the power to the computerized
control circuit inhibiting automatic door operation. The control circuit will
automatically reset when the door panel self engages.
6) Guide rail holding
beam: Shall be installed in guide rail on swing side of panels. It consists of
an emitter and a detector transmitting a pulsed infrared light beam across the
door opening.
2.03 ACTIVATING DEVICES
A.
Acusensor: Manufactured by NABCO ENTRANCES, INC. shall be used for
activating and/or a holding device. The Acusensor shall be supplied and
installed on one or both sides of operator housing to activate doors for
single or two-way traffic. Units shall be sealed for protection against dust,
moisture, and the elements. The Acusensor allows adjustment of detection beam
pattern with five selections. The Acusensor meets and exceeds the ANSI 156.10
Standards.
B.
Carpet Activators: Of sizes and colors required shall be manufactured
by NABCO ENTRANCES INC.
C.
Wall Switches: 6", 4-½" diameter stainless steel surface or
flush mounted, engraved or plain, as manufactured by NABCO ENTRANCES INC.
D.
Optional activators are available - See Product Catalog.
PART 3- EXECUTION
3.01 INSTALLATION
A.
Automatic door equipment shall be installed by factory-trained
installers in compliance with manufacturer’s recommendations and approved
shop drawings.
3.02 CLEANING AND PROTECTION
A. After installation,
clean framing members as recommended by the manufacturer. Aluminum surfaces in
contact with masonry, concrete or steel shall be protected from contact by use
of neoprene gaskets, where indicated, or a coat of bituminous paint to prevent
galvanic or corrosive action. Advise general contractor to protect unit from
damage during subsequent construction activities.
* COVER NOTE TO SPECIFICATION
WRITER
Indicate under
appropriate Section the following work by others:
ELECTRICAL INSTALLER shall furnish and
install all conduit and electrical wiring for activating devices and door
operators. A minimum of 5 amperes, 115 volts, A/C, 1-phase circuit shall be
furnished for each door operator, terminate and connect to operator control
panel, in operator housing.
CONCRETE INSTALLER shall prepare floor at
location of automatic entrance system to accommodate the surface or recessed
electric switch mats indicated on drawings.