GT SYSTEM 400 CONVERSION UNIT
USING THE GYRO SWING
SPRING CLOSE OPERATOR
SUGGESTED ARCHITECTURAL SPECIFICATIONS
SECTION 8
AUTOMATIC ENTRANCE SYSTEMS
PART 1 - GENERAL
1.01 DESCRIPTION
A.
Furnish and install automatic entrance equipment as indicated on
drawings and as specified.
B.
Related work specified elsewhere.
1. Electrical
Supply: Section__________
2. Floor
Preparation: Section__________
1.02 QUALITY ASSURANCE
A.
Manufacturer's Qualifications:
Products specified shall be represented by a
factory authorized and trained distributor. Distributor shall maintain a parts
inventory and trained personnel capable of providing service.
B.
Requirements of Regulatory Agencies:
1) Underwriters
Laboratory, Inc.
(UL):
Automatic entrance and/or exit doors shall be a UL listed system in
guide FDDR and/or guide FUXV.
C.
All automatic equipment to comply with ANSI A l56.10.
D.
Gyro Tech equipment as manufactured by NABCO ENTRANCES, INC. has been
specified and shall be quoted as the base bid. Other systems can be quoted
along with information specifically detailing the differences from the
following specification.
1.03 SUBMITTALS
A.
Shop drawings showing complete elevations, details and method of
anchorage to location; installation of hardware: size, shape, joints and
connections; and details of joining with other construction.
B.
Templates and diagrams and/or shop drawings as needed shall be
furnished to fabricators and installers of related work for coordination of
operators with doors, frames, hardware, concrete work, electrical work, and
other work.
C.
A copy of appropriate manual shall be provided to owner's engineer upon
completion of installation.
1.04 WARRANTY
A.
Warranty of power operators, controls and labor provided by automatic
door equipment installer against defects in material and workmanship at no
cost to owner, for a period of one year from date of substantial completion.
Provide warranty to owner after completion of installation.
1.05 COMPLIANCE
A.
A completed American Association of Automatic Door Manufacturer (AAADM)
form shall be submitted as proof of compliance with ANSI A156.10 Standard for
power operated pedestrian doors. Door(s) shall be inspected and form shall be
signed by an AAADM certified inspector prior to placing the door(s) in
operation.
PART 2 - PRODUCTS
2.01 APPROVED MANUFACTURER
A.
Automatic entrance equipment and controls shall be supplied by:
Ontario Door Controls
1350 Matheson Boulevard East
Unit 16, Mississauga
Ontario, Canada.
Phone: (905) 238 9222
Fax
: (905) 238 9279
e-mail:
products@automaticdoorsystems.com
Website: http://www.automaticdoorsystems.com
2.02 AUTOMATIC SWING DOOR SYSTEM
A. GYRO TECH System 400 (CU
surface-applied) as indicated on door schedule and details.
B.
Mode of Operation: Spring-Close. Gyro-Swing operator shall open door by
energizing motor and shall stop door by electrically reducing voltage and
stalling motor against mechanical stop. Door shall close by means of spring
energy, and closing force shall be controlled by gear system and motor being
used as dynamic brake without power. System shall operate as manual door
control in event of power failure. Manual operation shall require less than 15
lbs. force applied to door stile. Opening and closing speeds shall be
adjustable. Door operation shall not require any fluids or gases under
pressure to be used in opening and closing of door.
C.
Components:
1. Operator Housing
2. Gyro-Swing Power Operator
3. Electronic Control
4. Soft Start
5. Connecting Hardware
6. Breakaway Door Stop
la)
Operator Housing: GYRO- TECH Housing shall be 5-1/2"(139.7 mm)
wide by 5" (127.0mm) high aluminum extrusions enclosed with end caps and
shall be prepared for mounting to new or existing door frames. All structural
sections shall have a minimum thickness of 0.146" (3.7mm) and shall be
fabricated of 6063-T5 aluminum alloy.
1b) Finish: Aluminum shall have a standard
finish of AA-M12-C22-A31 (204 R1) or AA-M12-C22-A42 (dark bronze). Black and
special finishes available upon request.
2)
Gyro-Swing Power Operator: Completely assembled and sealed unit,
which shall include helical gear-driven transmission, overriding clutch (to
provide easy manual operation, spring-close). Mechanical spring and bearings,
all located in cast aluminum housing and filled with special lubricant for
extreme temperature conditions. Attached to transmission system shall be a DC
shunt-wound permanent magnet motor with sealed ball bearings. Motor shall
operate from 115-volt supply and require less than 5 amps at full power stall.
Complete unit shall be resilient mounted with provisions for easy replacement,
without removing door from pivots or frame.
3) Choose one of the following:
a)
Electrical Control: Shall be a microprocessor unit. To facilitate
service and continuing operations, the unit supplied with this swing unit
shall also be able to operate other doors supplied for the project including
sliding and folding types.
b)
Electrical Control: Self-contained unit including necessary
transformer, relays, rectifiers, and other electronic components for proper
operation and switching of Gyro-Swing power operator. Relays shall be plug-in
type for individual replacement. All connecting harnesses shall have
interlocking plugs. Controls shall also include time delay for normal cycle.
Control shall include safe-swing circuit as optional switching which
automatically limits power and slows door when approached from passive side.
4)
Soft Start: Energy limiter shall be a modular electronic current
control for the purpose of controlling torque to reasonably limit unnecessary
stress on entire entrance package.
5)
Connecting Hardware: Connect conversion unit (CU) drive arm to in-swing
door with a urethane covered roller, which shall ride in a track fabricated of
6061-T6 aluminum alloy attached to the top door rail where required for
pull-type operation. Out-swing doors shall be connected to operator by a
two-piece drive arm with self-aligning rod ends and connecting door bracket
for push-type operation.
6)
Emergency breakaway doorstop shall mount directly to the underside of
operator housing. It shall function as a stop on all centre pivoted
in-swinging doors. A force of not more than 50 LBF applied at the lock stile
shall cause the breakaway stop to rotate, disconnecting the power and allowing
the door to swing open l80 degrees opposite its normal travel. Swinging the
door into the normal mode of operation resets the breakaway doorstop and power
for normal automated operation.
2.03 ACTIVATING DEVICES
A.
Sensor Devices - Approach Side. The Acusensor as manufactured by NABCO
ENTRANCES, INC. shall be used. Sensing shall be provided in a rectangular
shaped pattern with sensing immediately next to the door system. To provide
optimum coverage to meet specific site conditions the sensing pattern shall be
adjustable both in width and depth of coverage while remaining at a full power
setting
B. 1)
Sensor Devices - Swing Side (Choose one) The Acusensor Rail system
shall be provided which includes an Acusensor mounted on the header plus guide
rails with a holding beam. Header mounted sensor shall be set up to provide
rectangular shaped coverage with sensing immediately next to the door system.
To provide optimum coverage to meet specific site conditions the sensing
pattern shall be adjustable both in width and depth of coverage while
remaining at full power setting.
2)
Sensor Devices - Swing Side (Choose one) The Acuswing system shall be
provided which includes two sensors mounted near the top of the door to
provide continuous sensing coverage on both sides of the door panel including
during the opening and closing operations. Coverage shall be provided a
minimum of 5" beyond the leading edge of the door
C.
Optional activators are available - See Product Catalog.
PART 3-EXECUTION
3.01 INSTALLATION
A. Automatic door equipment
shall be installed by factory-trained installers in compliance with
manufacturer's recommendations and approved shop drawings.
3.02 CLEANING AND PROTECTION
A.
After installation, clean framing members as recommended by
manufacturer. Aluminum surfaces in contact with masonry, concrete, and steel
shall be protected by use of neoprene gaskets where indicated, or a coat of
bituminous paint to prevent galvanic or corrosive action. Please advise
general contractor to protect unit from damage during subsequent construction
activities.
* COVER NOTE
TO SPECIFICATION WRITER
Indicate under
appropriate Section the following work by others.
ELECTRICAL INSTALLER shall furnish and
install all conduit and electrical wiring for activating devices and door
operators. A minimum of 5 amperes, 115-volt, A/C, 1-phase circuit shall be
furnished for each door operator, terminate and connect to operator control
panel in operator housing.
CONCRETE INSTALLER shall prepare floor at
location of automatic entrance system to accommodate the surface or recessed
electric switch mats as indicated on drawings.
GLAZING INSTALLER shall furnish, properly
prepare, and install aluminum doors with automatic swing door equipment,
automatic swing door operator housings, track and pivot assemblies will be
furnished to glazing contractor by manufacturer approved automatic entrance
contractor for installation. Approved fastening devices as indicated on
automatic swing door shop drawings must be used.