GT SYSTEM 500
STANDARD AUTOMATIC MODE
USING THE GYRO SWING SPRING CLOSE OPERATOR
SUGGESTED ARCHITECTURAL SPECIFICATIONS
SECTION 8
AUTOMATIC ENTRANCE SYSTEMS
PART 1 - GENERAL
1.01 DESCRIPTION
A. Furnish and install automatic
entrance equipment as indicated on drawings and as specified.
B.
Related work specified elsewhere.
1.
Electrical Supply: Section________
2.
Floor Preparation: Section________
1.02 QUALITY ASSURANCE
A.
Manufacturer's Qualifications:
Products specified shall be represented by a
factory authorized and trained distributor. Distributor shall maintain a parts
inventory and trained personnel capable of providing service.
B.
Requirements of Regulatory Agencies:
1.
Underwriters Laboratory, Inc. (UL): Automatic entrance and/or exit
doors shall be a UL listed system in guide FDDR and/or guide FUXV.
2.
Meets requirements of disabled in accordance with Federal Regulation
ANSI 117
C.
All automatic equipment to comply with ANSI A156.19.
D.
Gyro Tech equipment as manufactured by NABCO ENTRANCES, INC. has been
specified and shall be quoted as the base bid. Other systems may be quoted
along with information specifically detailing the differences from the
following specification.
1.03 SUBMITTALS
A.
Shop drawings showing complete elevations, details and method of
anchorage to location; installation of hardware; size, shape, joints and
connections; and details of joining with other construction.
B.
Templates and diagrams and/or shop drawings as needed shall be
furnished to fabricators and installers of related work for coordination of
operators with doors, frames, hardware, concrete work and other work.
C.
A copy of appropriate manual shall be provided to owner's engineer upon
completion of installation.
1.04 WARRANTY
A.
Warranty of power operators, controls and labor provided by automatic
door equipment installer against defects in material and workmanship at no
cost to owner, for a period of one year from date of substantial completion.
Provide warranty to owner after completion of installation.
PART 2-PRODUCTS
2.01 APPROVED DISTRIBUTOR
Ontario Door Controls
1350 Matheson Boulevard East
Unit 16, Mississauga
Ontario, Canada.
Phone: (905) 238 9222
Fax
: (905) 238 9279
e-mail:
products@automaticdoorsystems.com
Website: http://www.automaticdoorsystems.com
2.02 AUTOMATIC SWING DOOR SYSTEM
A.
GYRO TECH GT System 500 (surface applied): Automatic Swing door system
for physically challenged as indicated on door schedule and details.
B.
Mode of Operation: Spring Close. Gyro-Swing operator shall open door by
energizing motor and shall stop door by stalling motor against mechanical
stop. Door shall close slowly by means of spring energy, closing force shall
be controlled by gear system and motor being used as dynamic brake without
power. Complete automatic door cycle 18 to 20 seconds. Manual door operation
requires less than 12 lbs. of force applied to door stile. System shall also
operate as a manual door in event of power failure. Hold open time shall be
adjustable. Door operation shall not require any fluids or gases under
pressure to be used in opening and closing of door.
C.
Components:
1. Operator Housing
2. Gyro-Swing Power Operator
3. Electronic Control
4. Connecting Hardware
la)
Operator Housing: GYRO TECH Housing shall be 5-1/2" (139.7 mm)
wide by 5" (127.0 mm) high aluminum extrusions with finished end caps and
shall be prepared for mounting to new or existing door frames. All structural
sections shall have a minimum thickness of 0.146" (3.7 mm) and shall be
fabricated of 6063-T5 aluminum alloy.
1b)
Finish: Aluminum shall have a standard finish of AA-M12-C22-A31 (204 Rl)
or AA-M12-C22-A42 (dark bronze). Black and special finishes available upon
request.
2)
Gyro-Swing Power Operator:
Completely assembled and sealed unit which shall
include helical gear-driven transmission, overriding clutch (to provide easy
manual operation, spring-close), mechanical spring and bearings all located in
cast aluminum housing and filled with special lubricant for extreme
temperature conditions. Attached to transmission system shall be a DC
shunt-wound permanent magnet motor with sealed ball bearings. Motor shall
operate from 115-volt supply and require less than 5 amps at full power stall.
Complete unit shall be resilient mounted with provisions for easy replacement,
without removing door from pivots or frame.
3) Electrical Control:
Self-contained unit including necessary transformer, relays, rectifiers, and
other electronic components for proper operation and switching of Gyro-Swing
power operator. Relays shall be plug-in type for individual replacement. All
connecting harnesses shall have interlocking plugs. Controls shall also
include time delay for normal cycle. Control shall also include adjustable (0
to 60 seconds) time delay module.
4)
Connecting Hardware: Connect conversion unit (CU) drive arm to inswing
door with a urethane covered roller which shall ride in a track fabricated of
6061-T6 aluminum alloy attached to the top door rail where required for
pull-type operation. Outswing doors shall be connected to operator by a
two-piece drive arm with self-aligning rod ends and connecting door bracket
for push-type operation.
2.03 ACTIVATING DEVICES
A.
Wall Switches: 6" (152.4 mm) diameter stainless steel, surface or
flush mounted, engraved or plain, as manufactured by NABCO ENTRANCES, INC.
B.
Carpets: Of sizes and colors as required shall be manufactured by NABCO
ENTRANCES, INC.
C.
Optional activators are available
- See Product Catalog.
PART 3-EXECUTION
3.01 INSTALLATION
A.
Automatic door equipment shall be installed by factory-trained
installers in compliance with manufacturer's recommendations and approved shop
drawings
3.02 CLEANING AND PROTECTION
A. After installation, clean
framing members as recommended by manufacturer. Aluminum surfaces in contact
with masonry, concrete, and steel shall be protected by use of neoprene
gaskets where indicated, or a coat of bituminous paint to prevent galvanic or
corrosive action. Advise general contractor to protect unit from damage during
subsequent construction activities.
* COVER NOTE
TO SPECIFICATION WRITER
Indicate under
appropriate Section the following work by others.
ELECTRICAL INSTALLER shall furnish and
install all conduit and electrical wiring for activating devices and door
operators. A minimum of 5 amperes, 115-volt, A/C. 1-phase circuit shall be
furnished for each door operator, terminate and connect to operator control
panel in operator housing.
CONCRETE INSTALLER shall prepare floor at
location of automatic entrance system to accommodate the surface or recessed
electric switch mats as indicated on drawings.